  Datasheet File OCR Text:
 S524L50X51
16K-bit Serial EEPROM
Data Sheet
OVERVIEW
The S524L50X51 serial EEPROM has a 16 Kbits (2,048 bytes) capacity, supporting the standard I2CTM-bus serial interface. It is fabricated using Samsung's most advanced CMOS technology. One of its major features is a hardware-based write protection circuit for the entire memory area. Hardware-based write protection is controlled by the state of the write-protect (WP) pin. Using one-page write mode, you can load up to 16 bytes of data into the EEPROM in a single write operation. Another significant feature of the S524L50X51 is its support for fast mode and standard mode.
FEATURES
I2C-Bus Interface * * Two-wire serial interface Automatic word address increment Operating Characteristics * * Operating voltage: 2.0 V to 5.5 V Operating current -- Maximum write current: < 3 mA at 5.5 V EEPROM * * * * * * * 16 Kbits (2,048 bytes) storage area 16-byte page buffer Typical 3 ms write cycle time with auto-erase function Hardware-based write protection for the entire EEPROM (using the WP pin) EEPROM programming voltage generated on chip 1,000,000 erase/write cycles 100 years data retention * * -- Maximum read current: < 200 A at 5.5 V -- Maximum stand-by current: < 2 A at 2.0 V Operating temperature range -- - 25C to + 70C (commercial) -- - 40C to + 85C (industrial) * Operating clock frequencies -- 100 kHz at standard mode -- 400 kHz at fast mode Electrostatic discharge (ESD) -- 5,000 V (HBM) -- 400 V (MM) Packages * 8-pin DIP, SOP, and TSSOP
5-1
S524L50X51 SERIAL EEPROM
DATA SHEET
SDA
Start/Stop Logic
HV Generation Timing Control
WP
Control Logic
SCL
Slave Address Comparator
Word Address Pointer
Row decoder
EEPROM Cell Array 2,048 x 8 bits
A0 A1 A2 Column Decoder
Data Register
DOUT and ACK
Figure 5-1. S524L50X51 Block Diagram
5-2
DATA SHEET
S524L50X51 SERIAL EEPROM
VCC
WP
SCL SDA
S524L50X51
A0
A1
A2
VSS
NOTE:
The S524L50X51 is available in 8-pin DIP, SOP, and TSSOP package.
Figure 5-2. Pin Assignment Diagram
Table 5-1. S524L50X51 Pin Descriptions Name A0, A1, A2 VSS SDA Type - - I/O No internal connection Ground pin. Bi-directional data pin for the I C-bus serial data interface. Schmitt trigger input and open-drain output. An external pull-up resistor must be connected to VDD. Schmitt trigger input pin for serial clock input. Input pin for hardware write protection control. If you tie this pin to VCC, the write function is disabled to protect previously written data in the entire memory; if you tie it to VSS, the write function is enabled. This pin is internally pulled down to VSS. Single power supply.
2
Description
Circuit Type - - 3
SCL WP
Input Input
2 1
VCC
-
-
NOTE: See the following page for diagrams of pin circuit types 1, 2, and 3.
5-3
S524L50X51 SERIAL EEPROM
DATA SHEET
WP
SCL
Noise Filter
Figure 5-3. Pin Circuit Type 1
Figure 5-4. Pin Circuit Type 2
SDA Data Out
VSS Noise Filter
Data In
Figure 5-5. Pin Circuit Type 3
5-4
DATA SHEET
S524L50X51 SERIAL EEPROM
FUNCTION DESCRIPTION
I2C-BUS INTERFACE The S524L50X51 supports the I2C-bus serial interface data transmission protocol. The two-wire bus consists of a serial data line (SDA) and a serial clock line (SCL). The SDA and the SCL lines must be connected to VCC by a pull-up resistor that is located somewhere on the bus. Any device that puts data onto the bus is defined as a "transmitter" and any device that gets data from the bus is a "receiver." The bus is controlled by a master device which generates the serial clock and start/stop conditions, controlling bus access. Only one S524L50X51 devices can be connected to the I2C-bus as slaves (see Figure 56). Both the master and slaves can operate as a transmitter or a receiver, but the master device determines which bus operating mode would be active.
VCC
VCC
R
R
SDA SCL Master Bus Master (Transmitter/ Receiver) Slave
S524L50X51
Figure 5-6. Typical Configuration
5-5
S524L50X51 SERIAL EEPROM
DATA SHEET
I2C-BUS PROTOCOLS Here are several rules for I2C-bus transfers: -- A new data transfer can be initiated only when the bus is currently not busy. -- MSB is always transferred first in transmitting data. -- During a data transfer, the data line (SDA) must remains stable whenever the clock line (SCL) is High. The I2C-bus interface supports the following communication protocols: * * * Bus not busy: The SDA and the SCL lines remain in High level when the bus is not active. Start condition: A start condition is initiated by a High-to-Low transition of the SDA line while SCL remains in High level. All bus commands must be preceded by a start condition. Stop condition: A stop condition is initiated by a Low-to-High transition of the SDA line while SCL remains in High level. All bus operations must be completed by a stop condition (see Figure 5-7).
~ ~
SCL
~ ~
SDA
Start Condition
Data or Data ACK Valid Change
Stop Condition
Figure 5-7. Data Transmission Sequence * Data valid: Following a start condition, the data becomes valid if the data line remains stable for the duration of the High period of SCL. New data must be put onto the bus while SCL is Low. Bus timing is one clock pulse per data bit. The number of data bytes to be transferred is determined by the master device. The total number of bytes that can be transferred in one operation is theoretically unlimited. ACK (Acknowledge): An ACK signal indicates that a data transfer is completed successfully. The transmitter (the master or the slave) releases the bus after transmitting eight bits. During the 9th clock, which the master generates, the receiver pulls the SDA line low to acknowledge that it has successfully received the eight bits of data (see Figure 5-8). But the slave does not send an ACK if an internal write cycle is still in progress. In data read operations, the slave releases the SDA line after transmitting 8 bits of data and then monitors the line for an ACK signal during the 9th clock period. If an ACK is detected, the slave will continue to transmit data. If an ACK is not detected, the slave terminates data transmission and waits for a stop condition to be issued by the master before returning to its stand-by mode.
*
5-6
DATA SHEET
S524L50X51 SERIAL EEPROM
Master SCL Line
Bit 1
Bit 9
Data from Transmitter
ACK from Receiver ACK
Figure 5-8. Acknowledge Response From Receiver * Slave Address: After the master initiates a start condition, it must output the address of the device to be accessed. The most significant four bits of the slave address are called the "device identifier." The identifier for the S524L50X51 is "1010B". The next three bits (B2, B1, B0) are for block selection. They are used by the master to select which of the blocks of internal memory (1 block=256 words) are to be accessed. (see Table 5-2 below.) These bits are in effect the three most significant bits of the word address. Read/Write: The final (eighth) bit of the slave address defines the type of operation to be performed. If the R/W bit is "1", a read operation is executed. If it is "0", a write operation is executed. Table 5-2. Slave Address Byte Function Read Write Device Identifier b7 1 1 b6 0 0 b5 1 1 b4 0 0 b3 B2 B2 Block Select b2 B1 B1 b1 B0 B0 R/W Bit b0 1 0
*
5-7
S524L50X51 SERIAL EEPROM
DATA SHEET
BYTE WRITE OPERATION In a complete byte write operation, the master transmits the slave address, word address, and one data byte to the S524L50X51 slave device (see Figure 5-9).
Start
Slave Address
Word Address
Data
Stop
A C K
A C K
A C K
Figure 5-9. Byte Write Operation Following a start condition, the master sends the device identifier (4 bits), three "don't care" bits, and an R/W bit set to "0" onto the bus. Then the addressed S524L50X51 generates an ACK, and waits for the next byte. The next byte to be transmitted by the master is the word address. This 8-bit address is written into the word address pointer of the S524L50X51. When the S524L50X51 receives the word address, it responds by issuing an ACK and then waits for the next 8bit data. When it receives the data byte, the S524L50X51 again responds with an ACK. The master terminates the transfer by generating a Stop condition, at which time the S524L50X51 begins the internal write cycle. While the internal write cycle is in progress, all S524L50X51 inputs are disabled and the S524L50X51 does not respond to any additional request from the master.
5-8
DATA SHEET
S524L50X51 SERIAL EEPROM
PAGE WRITE OPERATION The S524L50X51 can also perform 16-byte page write operation. A page write operation is initiated in the same way as a byte write operation. However, instead of finishing the write operation after the first data byte is transferred, the master can transmit up to 15 additional bytes. The S524L50X51 responds with an ACK each time it receives a complete byte of data (see Figure 5-10).
Start
Slave Address
Word Address n
Data n
Data (<= n + 15)
Stop
... A C K A C K A C K A C K A C K
Figure 5-10. Page Write Operation The S524L50X51 automatically increments the word address pointer each time it receives a complete data byte. When one byte is received, the internal word address pointer increments to the next address so that the next data byte can be received. If the master transmits more than 16 bytes before it generates a stop condition to end the page write operation, the S524L50X51 word address pointer value "rolls over" and the previously received data is overwritten. If the master transmits less than 16 bytes and generates a stop condition, the S524L50X51 writes the received data to the corresponding EEPROM address. During a page write operation, all inputs are disabled and there would be no response to additional requests from the master until the internal write cycle is completed.
5-9
S524L50X51 SERIAL EEPROM
DATA SHEET
POLLING FOR AN ACK SIGNAL When the master issues a stop condition to initiate a write cycle, the S524L50X51 starts an internal write cycle. The master can then immediately begin polling for an ACK from the slave device to determine whether the write cycle is completed. To poll for an ACK signal in a write operation, the master issues a start condition followed by the slave address. As long as the S524L50X51 remains busy with the write operation, no ACK is returned. When the S524L50X51 completes the write operation, it returns an ACK and the master can then proceed with the next read or write operation (see Figure 5-11).
Send Write Command
Send Stop Condition to Initiate Write Cycle
Send Start Condition
Send Slave Address with R/W bit = "0"
No ACK = "0" ?
Yes Start Next Operation
Figure 5-11. Master Polling for an ACK Signal from a Slave Device
5-10
DATA SHEET
S524L50X51 SERIAL EEPROM
HARDWARE-BASED WRITE PROTECTION You can also write-protect the entire memory area of the S524L50X51. This method of write protection is controlled by the state of the Write Protect (WP) pin. When the WP pin is connected to VCC, any attempt to write a value to the memory is ignored. The S524L50X51 will acknowledge slave and word address, but it will not generate an acknowledge after receiving first byte of data. In this situation the write cycle will not be started when a stop condition is generated. By connecting the WP pin to VSS, the write function is allowed for the entire memory. These write protection features effectively change the EEPROM to a ROM in order to protect data from being overwritten. Whenever the write function is disabled, a slave address and a word address are acknowledged on the bus, but data bytes are not acknowledged. The WP pin is internally pulled down to VSS. CURRENT ADDRESS BYTE READ OPERATION The internal word address pointer maintains the address of the last word accessed, incremented by one. Therefore, if the last access (either read or write) was to the address "n", the next read operation would access data at address "n+1". When the S524L50X51 receives a slave address with the R/W bit set to "1", it issues an ACK and sends eight bits of data. In a current address byte read operation the master does not acknowledge the data, and it generates a Stop condition, forcing the S524L50X51 to stop the transmission (see Figure 5-12).
Start
Slave Address
Data
Stop
A C K
N O A C K
Figure 5-12. Current Address Byte Read Operation
5-11
S524L50X51 SERIAL EEPROM
DATA SHEET
RANDOM ADDRESS BYTE READ OPERATION Using random read operations, the master can access any memory location at any time. Before it issues the slave address with the R/W bit set to "1", the master must first perform a "dummy" write operation. This operation is performed in the following steps: 1. The master first issues a start condition, the slave address, and the word address to be read. (This step sets the internal word address pointer of the S524L50X51 to the desired address.) 2. When the master receives an ACK for the word address, it immediately re-issues a start condition followed by another slave address, with the R/W bit set to "1". 3. The S524L50X51 then sends an ACK and the 8-bit data stored at the pointed address. 4. At this point, the master does not acknowledge the transmission, generating a stop condition. 5. The S524L50X51 stops transmitting data and reverts to stand-by mode (see Figure 5-13).
Start
Slave Address
Word Address
Start
Slave Address
Data (n)
Stop
A C K
A C K
A C K
N O A C K
Figure 5-13. Random Address Byte Read Operation
5-12
DATA SHEET
S524L50X51 SERIAL EEPROM
SEQUENTIAL READ OPERATION Sequential read operations can be performed in two ways: current address sequential read operation, and random address sequential read operation. The first data is sent in either of the two ways, current address byte read operation or random address byte read operation described earlier. If the master responds with an ACK, the S524L50X51 continues transmitting data. If the master does not issue an ACK, generating a stop condition, the slave stops transmission, ending the sequential read operation. Using this method, data is output sequentially from address "n" followed by address "n+1". The word address pointer for read operations increments to all word addresses, allowing the entire EEPROM to be read sequentially in a single operation. After the entire EEPROM is read, the word address pointer "rolls over" and the S524L50X51 continues to transmit data for each ACK it receives from the master (see Figure 5-14).
Start
Slave Address
Data (n)
Data (n+x)
Stop
~ ~
A C K A C K N O A C K
A C K
Figure 5-14. Sequential Read Operation
5-13
S524L50X51 SERIAL EEPROM
DATA SHEET
ELECTRICAL DATA
Table 5-3. Absolute Maximum Ratings (TA = 25 C) Parameter Supply voltage Input voltage Output voltage Operating temperature Storage temperature Electrostatic discharge Symbol VCC VIN VO TA TSTG VESD Conditions - - - - - HBM MM Rating - 0.3 to + 7.0 - 0.3 to + 7.0 - 0.3 to + 7.0 - 40 to + 85 - 65 to + 150 5000 400 Unit V V V
C C
V
Table 5-4. D.C. Electrical Characteristics (TA = - 25 C to + 70 C (Commercial), - 40 C to + 85 C (Industrial), VCC = 2.0 V to 5.5 V) Parameter Input low voltage Input high voltage Input leakage current Output leakage current Output Low voltage Supply current Write Symbol VIL VIH ILI ILO VOL ICC1 ICC2 Read ICC3 ICC4 Stand-by current ICC5 ICC6 VIN = 0 to VCC VO = 0 to VCC IOL = 3 mA, VCC = 2.0 V VCC = 5.5 V, 400 kHz VCC = 2.0 V, 100 kHz VCC = 5.5 V, 400 kHz VCC = 2.0 V, 100 kHz VCC = SDA = SCL = 5.5 V, all other inputs = 0 V VCC = SDA = SCL = 2.0 V, all other inputs = 0 V Conditions SCL, SDA Min - 0.7 VCC - - - - - - - - - Typ - - - - - - - - - - - Max 0.3 VCC - 10 10 0.4 3 1 0.2 60 5 2 A A Unit V V A A V mA
5-14
DATA SHEET
S524L50X51 SERIAL EEPROM
Table 5-4. D.C. Electrical Characteristics (Continued) (TA = - 25 C to + 70 C (Commercial), - 40 C to + 85 C (Industrial), VCC = 2.0 V to 5.5 V) Parameter Input capacitance Symbol CIN Conditions 25 C, 1MHz, VCC = 5 V, VIN = 0 V, A0, A1, A2, SCL and WP pin 25 C, 1MHz, VCC = 5 V, VI/O = 0 V, SDA pin Min - Typ - Max 10 Unit pF
Input/Output capacitance
CI/O
-
-
10
Table 5-5. A.C. Electrical Characteristics (TA = - 25 C to + 70 C (Commercial), - 40 C to + 85 C (Industrial), VCC = 2.0 V to 5.5 V) Parameter Symbol Conditions VCC = 2.0 to 5.5 V (Standard Mode) Min External clock frequency Clock High time Clock Low time Rising time Falling time Start condition hold time Start condition setup time Data input hold time Data input setup time Stop condition setup time Bus free time Data output valid from clock low (2) Noise spike width Write cycle time
NOTES: 1. 2. Upon customers request, up to 400 kHz (Max.) in standard mode and 1 MHz in fast mode are available. When acting as a transmitter, the S524L50X51 must provide an internal minimum delay time to bridge the undefined period (minimum 300 ns) of the falling edge of SCL. This is required to avoid unintended generation of a start or stop condition.
VCC = 4.5 to 5.5 V (Fast Mode) Min 0 0.6 1.3 - - 0.6 0.6 0 0.1 0.6 1.3 - - - Max 400 (1) - - 0.3 0.3 - - - - - - 0.9 50 5
Unit
Max 100 - - 1 0.3 - - - - - - 3.5 100 5
(1)
Fclk tHIGH tLOW tR tF tHD:STA tSU:STA tHD:DAT tSU:DAT tSU:STO tBUF tAA tSP tWR
- - - SDA, SCL SDA, SCL - - - - - Before new transmission - - -
0 4 4.7 - - 4 4.7 0 0.25 4 4.7 0.3 - -
kHz s s s s s s s s s s s ns ms
5-15
S524L50X51 SERIAL EEPROM
DATA SHEET
tF SCL tSU:STA SDA In tLOW
tHIGH
tR
tHD:STA
tHD:DAT
tSU:DAT
tSU:STO
tAA SDA Out
tBUF
Figure 5-15. Timing Diagram for Bus Operations
~ ~
SCL
~~ ~~
SDA WORDn
8th Bit
ACK
tWR Stop Condition Start Condition
Figure 5-16. Write Cycle Timing Diagram
5-16
DATA SHEET
S524L50X51 SERIAL EEPROM
CHARACTERISTIC CURVES NOTE The characteristic values shown in the following graphs are based on actual test measurements. They do not, however, represent guaranteed operating values.
(Frequency = 100 kHz) 2.0
1.6 Temp = -40 C 1.2 I CC (mA) 0.8 Temp = -25 C Temp = 25 C Temp = 70 C Temp = 85 C 0.4
0 1.5 2.5 3.5 VCC (V) 4.5 5.5
Figure 5-17. Write Current
5-17
S524L50X51 SERIAL EEPROM
DATA SHEET
(Frequency = 100 kHz) 140 120 100 80 I CC (uA) 60 40 20 0 1.5 2.5 3.5 VCC (V) 4.5 5.5 Temp = -40 C Temp = -25 C Temp = 25 C Temp = 70 C Temp = 85 C
Figure 5-18. Read Current
(Frequency = 100 kHz) 1.5
1.2
0.9 I CC (uA) 0.6 Temp = -40 C Temp = -25 C Temp = 25 C 0.3 Temp = 70 C Temp = 85 C 0 1.5 2.5 3.5 VCC (V) 4.5 5.5
Figure 5-19. Stand-by Current
5-18
DATA SHEET
S524L50X51 SERIAL EEPROM
(TA = 25 C) 70 60 50 40 I OL (mA) 30 20 10 0 0 1 2 3 VOL (V) 4 5 6 VDD = 6 V VDD = 5 V VDD = 4 V VDD = 3 V
VDD = 2 V
Figure 5-20. Output Low Voltage
5-19
S524L50X51 SERIAL EEPROM
DATA SHEET
NOTES
5-20


▲Up To Search▲   

 